FLEXIBLE TRAILING CABLES
|
|
|
TRINITY Trailing Cables suitable for working voltage up to 1100 volts grade are manufactured to suit electrical equipment used in Coal Mines:
No. of Cores | Type | Identification | Cross-section (sq. mm.) |
Voltage Grade | Application |
Five | Flexible Trailing Cable | FT3, FT4, FT6 | 16 to 95 | 1.1 KV | For use in coal cutters and similar portable machines. |
Five | Flexible Trailing Cable | FTD3 | 6 | 1.1 KV | For use in drills etc. |
Five | Pliable Armored Flexible Cables | P3 | 6 to 35 | 1.1 KV | For use in conveyors, loaders and similar transportable machines. |
Two/Three | Pliable Armored Flexible Cables | PC1, PC2 | 2.5 & 4 | 1.1 KV | For use with remote control circuit |
Four/Five | Pliable Armored Flexible Cables for Coalface lighting | PL1, PL2 | 4 | 1.1 KV | For use in Coalface lighting |
SPECIFICATIONS
TRINITY FLEXIBLE TRAILING CABLES FOR COAL MINES AS PER IS: 691-1984.
ELASTOMER INSULATED POWER CABLES SUITABLE FOR OPERATING FROM 3.3 KV TO 11 KV CONFORMING TO IS: 9968 (PART-II)
These fall under Two Categories:-
- Cables for Fixed Installation
Tinned Annealed copper / aluminum conductor, heat resisting elastomer insulated (with conductor & insulation screened as required) Un-armored, Heavy duty or heavy duty HOFR Elastomeric compound sheathed overall, single core or 3 core type, cross section 16 sq. mm. to 1000 sq. mm.- Cables of Flexible Type
Tinned annealed copper conductor, heat resisting elastomer insulated (with conductor and insulation Screened as required) Unarmored / Armored (Armoring of pliable wire armor type or steel wire braiding), heavy duty HOFR elastomeric compound sheathed overall, single core or 3 core type, cross section 16 sq. mm. to 1000 sq. mm.
PLIABLE ARMORED FLEXIBLE TRAILING CABLES AS PER IS: 1026.
Range of Cables:
- Three and four cores pliable armored flexible cables with general service or heat resisting elastomeric insulation suitable for working voltage up to and including 1100V between conductors. These cables have 2 or 3 power cores plus one earth core laid up around a cradle separator. The nominal area of conductor is 6 sq. mm. - 300 sq. mm.
- Four core pliable armored flexible cables for earthed 3-phase system with heat resisting elastomeric insulation suitable for working voltages of 3.3 KV between conductors (Uo / U-1.9/3.3KV). These cables have 3 power cores plus one earth core laid up around a cradle separator. The nominal area of conductors is 16 sq. mm - 300 sq. mm.
- Four core pliable armored flexible cables for earthed 3-phase system with heat resisting elastomeric insulation suitable for working voltage of 6.6 KV between conductors (Uo / U-3.8/6.6KV). These cables have 3 power cores plus one earth core laid up around a cradle separator. The nominal area of the conductor is 16 sq. mm. - 300 sq. mm.
Applications:
Pliable armored cables are used for power supplies to remote control circuits, coal face lighting roadway services and equipment that are moved occasionally such as coal conveyers and loaders.